PICOSCOPE® 9300 SERIES

Sampling Oscilloscopes to 30 GHz with TDR/TDT and Optical models


주요사양 :

  • 15 TS/s (64 fs) sequential sampling
  • Up to 15 GHz prescaled, 2.5 GHz direct trigger and 11.3 Gb/s clock recovery
  • 업계 최고의 16-bit 1 MS/s ADC and 60 dB dynamic range
  • Eye and mask testing to 16 Gb/s with up to 223–1 pattern lock
  • Intuitive, touch-compatible Windows user interface
  • Comprehensive built-in measurements, histogramming and editable data mask library
  • Integrated, differential, deskewable TDR/TDT step generator


  • 아래의 table에서 PICOSCOPE® 9300 SERIES 의 모델을 확인하세요.
    Oscilloscope – vertical (analog) 9300-15 models 9300-20 models 9300-25 models
    Number of channels PicoScope 9341: 4
    All other models: 2
    Acquisition timing Selectable simultaneous or alternate acquisition
    Bandwidth, Full 15 GHz 20 GHz 25 GHz
    Bandwidth, Narrow 8 GHz 10 GHz 12 GHz
    Pulse response rise time, full bandwidth 23.4 ps (10% to 90%, calculated) 17.5 ps (10% to 90%, calculated) 14.0 ps (10% to 90%, calculated)
    Pulse response rise time, narrow bandwidth 43.8 ps (10% to 90%, calculated) 35.0 ps (10% to 90%, calculated) 29.2 ps (10% to 90%, calculated)
    Noise, full bandwidth < 1.2 mV RMS typical, < 1.6 mV RMS maximum < 1.5 mV RMS typical, < 2.0 mV RMS maximum < 1.9 mV RMS typical, < 2.5 mV RMS maximum
    Noise, narrow bandwidth < 0.7 mV RMS typical, < 0.9 mV RMS maximum < 0.8 mV RMS typical, < 1.1 mV RMS maximum < 1.0 mV RMS typical, < 1.3 mV RMS maximum
    Noise with averaging 100 μV RMS system limit, typical
    Operating input voltage with digital feedback 1 V p-p with ±1 V range (single-valued)
    Operating input voltage without digital feedback ±400 mV relative to channel offset (multi-valued)
    Sensitivity 1 mV/div to 500 mV/div in 1-2-5 sequence with 0.5% fine increments
    Resolution 16 bits, 40 μV/LSB
    Accuracy ±2% of full scale ±2 mV over nominal temperature range (assuming temperature-related calibrations are performed)
    Nominal input impedance (50 ±1) Ω
    Input connectors 2.92 mm (K) female, compatible with SMA and PC3.5

    Timebase (Sequential time sampling mode)
    Ranges 5 ps/div to 3.2 ms/div (main, intensified, delayed, or dual delayed)
    Delta time interval accuracy For > 200 ps/div: ±0.2% of delta time interval ± 12 ps
    For < 200 ps/div: ±5% of delta time interval ± 5 ps
    Time interval resolution 64 fs
    Channel deskew 1 ps resolution, 100 ns max.

    Triggers
    Trigger sources All models: external direct, external prescaled, internal direct and internal clock triggers.
    PicoScope 9302 and 9321 only: external clock recovery trigger
    External direct trigger bandwidth and sensitivity DC to 100 MHz : 100 mV p-p; to 2.5 GHz: 200 mV p-p
    External direct trigger jitter 1.8 ps RMS (typ.) or 2.0 ps RMS (max.) + 20 ppm of delay setting
    Internal direct trigger bandwidth and sensitivity DC to 10 MHz: 100 mV p-p; to 100 MHz: 400 mV p-p (channels 1 and 2 only)
    Internal direct trigger jitter 25 ps RMS (typ.) or 30 ps RMS (max.) + 20 ppm of delay setting (channels 1 and 2 only)
    External prescaled trigger bandwidth and sensitivity 1 to 14 GHz, 200 mV p-p to 2 V p-p 1 to 14 GHz, 200 mV p-p to 2 V p-p
    14 to 15 GHz, 500 mV p-p to 2 V p-p
    External prescaled trigger jitter 1.8 ps RMS (typ.) or 2.0 ps RMS (max.) + 20 ppm of delay setting
    Pattern sync trigger clock frequency 10 MHz to 14 GHz 10 MHz to 14 GHz 10 MHz to 15 GHz
    Pattern sync trigger pattern length 7 to 8 388 607 (223− 1)

    Clock recovery (PicoScope 9302 and 9321)
    Clock recovery trigger data rate and sensitivity 6.5 Mb/s to 100 Mb/s: 100 mV p-p
    >100 Mb/s to 11.3 Gb/s: 20 mV p-p
    Recovered clock trigger jitter 1 ps (typ.) or 1.5 ps (max.) + 1.0% of unit interval
    Maximum safe trigger input voltage ±2 V (DC + peak AC)
    Input characteristics 50 Ω, AC coupled
    Input connector SMA (F)

    Acquisition
    ADC resolution 16 bits
    Digitizing rate with digital feedback (single-valued) DC to 1 MHz
    Digitizing rate without digital feedback (multi-valued) DC to 40 kHz
    Acquisition modes Sample (normal), average, envelope
    Data record length 32 to 32 768 points (single channel) in x2 sequence

    Display
    Styles Dots, vectors, persistence, gray-scaling, color-grading
    Persistence time Variable or infinite
    Screen formats Auto, single YT, dual YT, quad YT, XY, XY + YT, XY + 2 YT

    Measurement and analysis
    Markers Vertical bars, horizontal bars (measure volts) or waveform markers
    Automatic measurements Up to 10 at once
    Measurements, X parameters Period, frequency, pos/neg width, rise/fall time, pos/neg duty cycle, pos/neg crossing, burst width, cycles, time at max/min, pos/neg jitter ppm/RMS
    Measurements, Y parameters Max, min, top, base, peak-peak, amplitude, middle, mean, cycle mean, AC/DC RMS, cycle AC/DC RMS, pos/neg overshoot, area, cycle area
    Measurements, trace-to-trace Delay 1R-1R, delay 1F-1R, delay 1R-nR, delay 1F-nR, delay 1R-1F, delay 1F-1F, delay 1R-nF, delay 1F-nF, phase deg/rad/%, gain, gain dB
    Eye measurements, X NRZ Area, bit rate, bit time, crossing time, cycle area, duty cycle distortion abs/%, eye width abs/%, rise/fall time, frequency, period, jitter p-p/RMS
    Eye measurements, Y NRZ AC RMS, average power lin/dB, crossing %/level, extinction ratio dB/%/lin, eye amplitude, eye height lin/dB, max/min, mean, middle, pos/neg overshoot, noise p-p/RMS one/zero level, p-p, RMS, S/N ratio lin/dB
    Eye measurements, X RZ Area, bit rate/time, cycle area, eye width abs/%, rise/fall time, jitter p-p/RMS fall/rise, neg/pos crossing, pos duty cycle, pulse symmetry, pulse width
    Eye measurements, Y RZ AC RMS, average power lin/dB, contrast ratio lin/dB/%, extinction ratio lin/dB/%, eye amplitude, eye high lin/dB, eye opening, max, min, mean, middle, noise p-p/RMS one/zero, one/zero level, peak-peak, RMS, S/N
    Histogram Vertical or horizontal

    Math functions
    Mathematics Up to four math waveforms can be defined and displayed
    Math functions, arithmetic +, −, ×, ÷, ceiling, floor, fix, round, absolute, invert, (x+y)/2, ax+b
    Math functions, algebraic ex, ln, 10x, log10, ax, loga, d/dx, integrate, x2, sqrt, x3, xa, x−1, sqrt(x2 +y2)
    Math functions, trigonometric sin, sin−1, cos, cos−1, tan, tan−1, cot, cot−1, sinh, cosh, tanh, coth
    Math functions, FFT Complex FFT, complex inverse FFT, magnitude, phase, real, imaginary
    Math functions, combinatorial logic AND, NAND, OR, NOR, XOR, XNOR, NOT
    Math functions, interpolation Linear, sin(x)/x, trend, smoothing
    Math functions, other Custom formula
    FFT Up to two FFTs simultaneously
    FFT window functions Rectangular, Hamming, Hann, flat-top, Blackman–Harris, Kaiser–Bessel
    Eye diagram Automatically characterizes NRZ and RZ eye patterns based on statistical analysis of waveform

    Mask tests
    Mask geometry Acquired signals are tested for fit outside areas defined by up to eight polygons. Standard or user-defined masks can be selected.
    Built-in masks, SONET/SDH OC1/STMO (51.84 Mb/s) to FEC 1071 (10.709 Gb/s)
    Built-in masks, Ethernet 1.25 Gb/s 1000Base-CX Absolute TP2 to 10xGB Ethernet (12.5 Gb/s)
    Built-in masks, Fibre Channel FC133 (132.8 Mb/s) to 10x Fibre Channel (10.5188 Gb/s)
    Built-in masks, PCI Express R1.0a 2.5G (2.5 Gb/s) to R2.1 5.0G (5 Gb/s)
    Built-in masks, InfiniBand 2.5G (2.5 Gb/s) to 5.0G (5 Gb/s)
    Built-in masks, XAUI 3.125 Gb/s
    Built-in masks, RapidIO Level 1, 1.25 Gb/s to 3.125 Gb/s
    Built-in masks, SATA 1.5G (1.5 Gb/s) to 3.0G (3 Gb/s)
    Built-in masks, ITU G.703 DS1 (1.544 Mb/s) to 155 Mb (155.520 Mb/s)
    Built-in masks, ANSI T1.102 DS1 (1.544 Mb/s) to STS3 (155.520 Mb/s)
    Built-in masks, G.984.2 XAUI-E Far (3.125 Gb/s)
    Built-in masks, USB USB 3.0 (5 Gb/s), USB 3.1 (10 Gb/s)

    Signal generator output
    Modes Pulse, PRBS NRZ/RZ, 500 MHz clock, trigger out
    Period range, pulse mode 8 ns to 524 μs
    Bit time range, NRZ/RZ mode 4 ns to 260 μs
    NRZ/RZ pattern length 27−1 to 215−1

    TDR pulse outputs PicoScope 9311-15 PicoScope 9311-20
    Number of output channels 1 2 (1 differential pair)
    Output enable Yes Independent or locked control for each source
    Pulse polarity Positive-going from zero volts Channel 1: positive-going from zero volts
    Channel 2: negative-going from zero volts
    Rise time (20% to 80%) 60 ps guaranteed
    Amplitude 2.5 V to 7 V into 50 Ω
    Amplitude adjustment 5 mV increments
    Amplitude accuracy ±10%
    Offset  
    Output amplitude safety limit Adjustable from 2.5 V to 8 V
    Output pairing N/A Amplitudes and limit paired or independent
    Period range 1 μs to 60 ms
    Period accuracy ±100 ppm
    Width range 200 ns to 4 μs, 0% to 50% duty cycle
    Width accuracy ±10% of width ±100 ns
    Deskew between outputs N/A −1 ns to +1 ns typical, in 1 ps increments
    Timing modes Step, coarse timebase, pulse
    Impedance 50 Ω
    Connectors on scope SMA(f) SMA(f) x 2

    TDR pre-trigger output  
    Polarity Positive-going from zero volts
    Amplitude 700 mV typical into 50 Ω
    Pre-trigger 25 ns to 35 ns typical, adjustable in 5 ps increments
    Pre-trigger to output jitter 2 ps max.  

    TDT system PicoScope 9311-15 PicoScope 9311-20
    Number of TDT channels 1 2
    Incident rise time (combined oscilloscope and pulse generator, 10% to 90%) 65 ps or less 60 ps or less, each polarity
    Jitter 3 ps + 20 ppm of delay setting, RMS, max.
    Corrected rise time Min. 50 ps or 0.1 x time/div, whichever is greater, typical
    Max. 3 x time/div, typical
    Corrected aberrations = 0.5% typical

    TDR system PicoScope 9311-15 PicoScope 9311-20
    Number of channels 1 2
    Incident rise time (combined oscilloscope, step generator and TDR kit, 10% to 90%) 65 ps or less 60 ps or less, each polarity
    Reflected step amplitude, from short or open 25% of input pulse amplitude, typical
    Reflected rise time (combined oscilloscope, step generator and TDR kit, 10% to 90%) 65 ps or less @ 50 Ω termination 60 ps or less @ 50 Ω termination, each polarity
    Corrected rise time Minimum: 50 ps or 0.1 x time/div, whichever is greater, typical.
    Maximum: 3 x time/div, typical.
    Corrected aberration ≤ 1% typical
    Measured parameters Propagation delay, gain, gain dB

    TDR/TDT scaling  
    TDT vertical scale volts, gain (10 m/div to 100 /div)
    TDR vertical scale Volts, rho (10 mrho/div to 2 rho/div), ohm (1 ohm/div to 100 ohm/div)
    Horizontal scale Time (800 ns/div max.) or distance (meter, foot, inch)
    Distance preset units Propagation velocity (0.1 to 1.0) or dielectric constant (1 to 100)

    Optical/electrical converter (PicoScope 9321-20)
    Bandwidth (−3 dB) 9.5 GHz typical
    Effective wavelength range 750 nm to 1650 nm
    Calibrated wavelengths 850 nm (MM), 1310 nm (MM/SM), 1550 nm (SM)
    Transition time 51 ps typical (10% to 90% calculated from tR = 0.48/optical BW)
    Noise 4 μW (1310 & 1550 nm), 6 μW (850 nm) maximum @ full electrical bandwidth
    DC accuracy ±25 μW ±10% of full scale
    Maximum input peak power +7 dBm (1310 nm)
    Fiber input Single-mode (SM) or multi-mode (MM)
    Fiber input connector FC/PC
    Input return loss SM: −24 dB typical
    MM: −16 dB typical, −14 dB maximum

    General
    Temperature range, operating +5 °C to +35 °C
    Temperature range for stated accuracy Within 2 °C of last autocalibration
    Temperature range, storage −20 °C to +50 °C
    Calibration validity period 1 year
    Power supply voltage +12 V DC ± 5%
    Power supply current 1.7 A max.
    Mains adaptor Universal adaptor supplied
    PC connection USB 2.0 (compatible with USB 3.0)
    LAN connection 10/100 Mbit/s
    PC requirements Microsoft Windows XP (SP2 or SP3), Vista, 7, 8 or 10.
    32‑bit or 64‑bit versions.
    Dimensions 170 mm x 285 mm x 40 mm (W x D x H)
    Weight 1.3 kg max.
    Compliance FCC (EMC), CE (EMC and LVD)
    Warranty -years

    악세사리